MantisBT

View Issue Details Jump to Notes ] Related Changesets ] Issue History ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0000102WebSolarLogFrontendpublic2013-07-09 14:392013-07-26 16:45
Reporterarno58 
Assigned Tomdiphoorn 
PrioritynormalSeveritytrivialReproducibilityalways
StatusresolvedResolutionfixed 
PlatformLinux raspberrypiOSLinux raspberrypi 3.6.11+OS Version456
Product VersionRelease 1.0.0 
Target VersionRelease 1.1.0Fixed in VersionRelease 1.1.0 
Summary0000102: Incorrect label names on button in tab month
DescriptionIn tab Month the buttons belonging to "Max Grid Power", "kWh" and "The best/worst day" have the wrong name and in my case the third button (weather) does not have to be there.
The names should be:
Max Grid Power kWh
inverter 1 inverter 1
inverter 2 inverter 2

The best/worst day
inverter 1
inverter 2
TagsNo tags attached.
Attached Files

- Relationships

-  Notes
(0000110)
arno58 (reporter)
2013-07-09 15:16

On the Other Tab you have used the correct names
(0000141)
mdiphoorn (administrator)
2013-07-26 16:34

Redesigned the page for better multi inverter support. Also only show production devices.

- Issue History
Date Modified Username Field Change
2013-07-09 14:39 arno58 New Issue
2013-07-09 15:16 arno58 Note Added: 0000110
2013-07-26 16:33 mdiphoorn Assigned To => mdiphoorn
2013-07-26 16:33 mdiphoorn Status new => assigned
2013-07-26 16:34 mdiphoorn Note Added: 0000141
2013-07-26 16:34 mdiphoorn Status assigned => resolved
2013-07-26 16:34 mdiphoorn Fixed in Version => Release 1.1.0
2013-07-26 16:34 mdiphoorn Resolution open => fixed
2013-07-26 16:34 mdiphoorn Product Version => Release 1.0.0
2013-07-26 16:34 mdiphoorn Target Version => Release 1.1.0
2013-07-26 16:45 Changeset attached => SourceForge trunk r1149


Copyright © 2000 - 2019 MantisBT Team